Filter

Filter

Size of Microphone

Polarization

Application

Contact Testing

Sound Field

Standards

Axis

Sensitivity

Output Type

Size of Preamplifier

Acoustic Imaging

CRYSOUND acoustic cameras offer cutting-edge solutions for precise leak detection, partial discharge identification, and mechanical fault diagnosis. Equipped with high-performance microphone arrays and cutting-edge algorithms, our acoustic imaging cameras provide unparalleled precision and reliability. Each of our acoustic imagers is designed to enhance safety, efficiency, and performance across diverse industries.
CRY3717-S01 Coupler Set

CRY3717-S01 Coupler Set

Nominal Sensitivity 50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response 100Hz to 8kHz±2dB
Dynamic Range 12dB to 134dB
Get Quote
CRY3719-S01 Coupler Set

CRY3719-S01 Coupler Set

Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 125Hz to 8kHz
Dynamic Range 23dB to 146dB
Get Quote
CRY3721-S01 Ear Simulator Set

CRY3721-S01 Ear Simulator Set

Nominal Sensitivity 354 mV/Pa,-9 dB re 1V/Pa
Frequency Response 20 Hz to 20 kHz
Dynamic Range 7.5dBA to 115dB
Get Quote
CRY3711-S01 Ear Simulator Set

CRY3711-S01 Ear Simulator Set

Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Dynamic Range 23dB to 146dB
Get Quote
CRY3718-S01 Ear Simulator Set IEC60318-1

CRY3718-S01 Ear Simulator Set IEC60318-1

Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Standards IEC 60318-1、 ITU-T P.57 Type 1
Get Quote
CRY3717 IEC 60318-3 Coupler

CRY3717 IEC 60318-3 Coupler

Frequency Response 100Hz to 8kHz±2dB
Standards IEC60318-3
Equivalent Volume 6cc
Get Quote
CRY3719 Coupler IEC 60318-5

CRY3719 Coupler IEC 60318-5

Frequency Response 125Hz to 8kHz
Equivalent Volume 2cc
Standards IEC60318-5, ANSI S3.7、 GB/T 20441.4-2006
Get Quote
CRY3711 Ear Simulator IEC60318-4

CRY3711 Ear Simulator IEC60318-4

Nominal Sensitivity 12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response 100Hz to 10kHz ±1dB(Simulated human ear impedance)、 20Hzto 16kHz(Coupling cavity use)
Dynamic Range 23dB to 160dB
Get Quote
CRY3721 Ear Simulator IEC60318-4, Low-Noise

CRY3721 Ear Simulator IEC60318-4, Low-Noise

Standards IEC 60318-4, ITU-T P.57 Type 2
Equivalent Volume 1.26cc
Weight 50g
Get Quote
CRY3718 Ear Simulator IEC60318-1

CRY3718 Ear Simulator IEC60318-1

Frequency Response 100Hz to 4kHz ±1dB(Simulated human ear impedance)、 20Hz to 16kHz(Coupling cavity use)
Standards IEC 60318-1、 ITU-T P.57 Type 1、 GB/T 25498.1-2010
Weight 147g
Get Quote
Support Support
Product Catalogs Product Catalogs Solutions Solutions User Manuals User Manuals Software Download Software Download Product Inquiry Product Inquiry Schedule Demo Schedule Demo Technical Support Technical Support +86-571-88225128 +86-571-88225128
Request Quote 0
Request Quote
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.