Measure Sound Better
Filter
Filter
Size of Microphone
Polarization
Application
Contact Testing
Sound Field
Standards
Axis
Sensitivity
Output Type
Size of Preamplifier
Acoustic Imaging
CRYSOUND acoustic cameras offer cutting-edge solutions for precise leak detection, partial discharge identification, and mechanical fault diagnosis. Equipped with high-performance microphone arrays and cutting-edge algorithms, our acoustic imaging cameras provide unparalleled precision and reliability. Each of our acoustic imagers is designed to enhance safety, efficiency, and performance across diverse industries.
CRY446 Accelerometer, Triaxial, 10mv/g, ±500g pk, 1Hz to 5kHz
Measuring Range (peak)
±500g pk
Sensitivity (25℃)
10mV/g(160Hz)
Frequency Response
1Hz to 5kHz(±1dB)
CRY438 IEPE Accelerometer, 1 Axis, 10mv/g, ±500g pk, 1Hz to 10kHz
Measuring Range (Peak)
±500g
Sensitivity (25℃)
10mV/g (160Hz)
Frequency Response
1Hz to 10kHz(±1dB); 0.6Hz to 20KHz(±3dB)
CRY445 Accelerometer, Triaxial, 100mv/g, ±80g pk, 1Hz to 4kHz
Measuring Range (peak)
±80g pk
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
1Hz to 4kHz(±1dB); 0.5Hz to 8kHz(±3dB)
CRY443 Accelerometer, Triaxial, 50mv/g, ±100g pk, 1Hz to 4kHz
Measuring Range (peak)
±100g pk
Sensitivity (25℃)
50mV/g(160Hz)
Frequency Response
1Hz to 4kHz(±10%); 0.7Hz to 8kHz(±3dB)
CRY442 Accelerometer, Triaxial, 100mv/g, ±50g pk, 0.5Hz to 5kHz
Measuring Range (peak)
±50g pk
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
0.5Hz to 5kHz(±1dB)
CRY441 Charge Accelerometer, 1 Axis, 5pC/g, ±2500g pk, 1Hz to 10kHz
Dynamic Specification
±2500g pk
Measuring Range (peak)
5pC/g(160Hz)
Sensitivity (25℃)
1Hz to 10kHz(±1dB)
CRY437 Accelerometer, 1 Axis, 10mv/g, ±500g pk, 2Hz to 8kHz
Measuring Range (peak)
±500g pk
Sensitivity (25℃)
10mV/g(160Hz)
Frequency Response
2Hz to 8kHz(±1dB)
CRY436 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 1Hz to 12kHz
Measuring Range (peak)
±50g pk
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
1Hz to 12kHz(±10%); 0.5Hz to 20kHz(±3dB)
CRY435 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 1Hz to 6kHz
Dynamic Specification
±50g pk
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
1Hz to 6kHz(±10%); 0.5Hz to10kHz(±3dB)
CRY434 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 0.5Hz to 8kHz
Measuring Range (peak)
±50g pk
Sensitivity (25℃)
100mV/g(160Hz)
Frequency Response
0.5Hz to 8kHz(±1dB)
CRY433 Accelerometer, 1 Axis, 100mv/g, ±50g pk, 0.5Hz to 8kHz
Measuring Range (peak)
±50g pk
Measuring Range (peak)
100mV/g(160Hz)
Frequency Response
0.5 Hz to 8 kHz(±1 dB)
CRY432 Accelerometer, 1 Axis, 5mv/g, ±1000g pk, 1Hz to 12kHz
Measuring Range (Peak)
±1,000g pk
Sensitivity (25℃)
5mV/g(160Hz)
Frequency Response
1Hz to 12kHz(±1dB)
CRY431 IEPE Accelerometer, 1 Axis, 5mv/g, ±1000g pk, 1Hz to 12kHz
Measuring Range (Peak)
±1000g
Sensitivity (25℃)
5mV/g (160Hz)
Frequency Response
1Hz to 12kHz(±1dB)