Measure Sound Better
Filter
Filter
Size of Microphone
Polarization
Application
Contact Testing
Sound Field
Standards
Axis
Sensitivity
Output Type
Size of Preamplifier
Acoustic Imaging
CRYSOUND acoustic cameras offer cutting-edge solutions for precise leak detection, partial discharge identification, and mechanical fault diagnosis. Equipped with high-performance microphone arrays and cutting-edge algorithms, our acoustic imaging cameras provide unparalleled precision and reliability. Each of our acoustic imagers is designed to enhance safety, efficiency, and performance across diverse industries.
CRY3101-S01 Free-Field Microphone Set, 1", 50mV/Pa
Field Type
Free-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
4Hz to 16kHz±2dB
CRY3102-S01 Pressure-Field Microphone Set, 1", 50mV/Pa
Field Type
Pressure-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
4Hz to 8kHz±2dB
CRY3201-S01 Free-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Free-field
Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 40kHz±2dB
CRY3202-S01 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Pressure-field
Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3202-S02 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Pressure-field
Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3203-S01 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Free-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3203-S02 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Free-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3204-S01 Pressure-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Pressure-field
Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 10kHz±2dB
CRY3213 NVH Measurement Microphone
Field Type
Free-field
Sensitivity
50 mV/Pa, -26±2 dB re 1V/Pa
Frequency Response
3.15 Hz-20 kHz ±2 dB
CRY3261-S02 Ultra-Low-Noise Free-Field Microphone Set, 1/2", 450mV/Pa
Field Type
Free-field
Sensitivity
450 mV/Pa, -7 dB±2dB re 1V/Pa
Frequency Response
10 Hz to 16kHz ±2dB; 6 Hz to 20kHz ±3dB
CRY3401-S01 Free-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type
Free-field
Sensitivity
15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response
4Hz to 40kHz±2dB
CRY3402-S01 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type
Pressure-field
Sensitivity
1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response
4Hz to 70kHz±2dB
CRY3402-S02 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type
Pressure-field
Sensitivity
1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response
4Hz to 70kHz±2dB
CRY3403-S01 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type
Free-field
Sensitivity
4mV/Pa, -48±3dB re 1V/Pa
Frequency Response
4Hz to 90kHz±2dB
CRY3403-S02 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type
Free-field
Sensitivity
4mV/Pa, -48±3dB re 1V/Pa
Frequency Response
4Hz to 90kHz±2dB
CRY3404-S01 Pressure-Field Microphone Set, 1/4", 0.56mV/Pa
Field Type
Pressure-field
Sensitivity
0.56mV/Pa, -65±3dB re 1V/Pa
Frequency Response
10Hz to 20kHz±2dB
CRY3406-S01 Pressure-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type
Pressure-field
Sensitivity
15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response
4Hz to 20kHz±2dB
CRY3408-S01 Pressure-field Prepolarized High-level Microphone Set, 1/4", 0.14mV/Pa
Field Type
Pressure-field
Sensitivity
0.14 mV/Pa, -77±3 dB re 1V/Pa
Frequency Response
10 Hz to 20 kHz ±2 dB