Measure Sound Better
Filter
Filter
Size of Microphone
Polarization
Application
Contact Testing
Sound Field
Standards
Axis
Sensitivity
Output Type
Size of Preamplifier
Microphone Sets
CRYSOUND measurement microphone sets with matched preamplifiers—free-field or pressure-field, 1/4″, 1/2″ and 1″ options for precise acoustic testing.
CRY3101-S01 Free-Field Microphone Set, 1", 50mV/Pa
Field Type
Free-field
Noominal Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
4Hz to 16kHz±2dB
CRY3102-S01 Pressure-Field Microphone Set, 1", 50mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
4Hz to 8kHz±2dB
CRY3201-S01 Free-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Free-field
Noominal Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 40kHz±2dB
CRY3202-S01 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3202-S02 Pressure-Field Microphone Set, 1/2", 12.5mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
12.5mV/Pa, -38±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3203-S01 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Free-field
Noominal Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3203-S02 Free-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Free-field
Noominal Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 20kHz±2dB
CRY3204-S01 Pressure-Field Microphone Set, 1/2", 50mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
50mV/Pa, -26±1.5dB re 1V/Pa
Frequency Response
3.15Hz to 10kHz±2dB
CRY3213 NVH Measurement Microphone
Field Type
Free-field
Sensitivity(±2 dB)
50 mV/Pa, -26 dB re 1V/Pa
Frequency Response
3.15 Hz-20 kHz ±2 dB
CRY3261-S02 Free-Field Microphone Set, 1/2", 450mV/Pa
Field Type
Free-field
Noominal Sensitivity
450 mV/Pa, -7 dB±2dB re 1V/Pa
Frequency Response
10 Hz to 16kHz ±2dB; 6 Hz to 20kHz ±3dB
CRY3401-S01 Free-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type
Free-field
Noominal Sensitivity
15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response
4Hz to 40kHz±2dB
CRY3402-S01 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response
4Hz to 70kHz±2dB
CRY3402-S02 Pressure-Field Microphone Set, 1/4", 1.6mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
1.6mV/Pa, -56±3dB re 1V/Pa
Frequency Response
4Hz to 70kHz±2dB
CRY3403-S01 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type
Free-field
Noominal Sensitivity
4mV/Pa, -48±3dB re 1V/Pa
Frequency Response
4Hz to 90kHz±2dB
CRY3403-S02 Free-Field Microphone Set, 1/4", 4mV/Pa
Field Type
Free-field
Noominal Sensitivity
4mV/Pa, -48±3dB re 1V/Pa
Frequency Response
4Hz to 90kHz±2dB
CRY3404-S01 Pressure-Field Microphone Set, 1/4", 0.56mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
0.56mV/Pa, -65±3dB re 1V/Pa
Frequency Response
10Hz to 20kHz±2dB
CRY3406-S01 Pressure-Field Microphone Set, 1/4", 15.8mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
15.8mV/Pa, -36±1.5dB re 1V/Pa
Frequency Response
4Hz to 20kHz±2dB
CRY3408-S01 Pressure-field Prepolarized High-level Microphone Set, 1/4", 0.14mV/Pa
Field Type
Pressure-field
Noominal Sensitivity
0.14 mV/Pa, -77 dB re 1V/Pa
Frequency Response
10 Hz to 20 kHz ±2 dB