Shop – Sound and Vibration Measurement & Testing – CRYSOUND https://design.crysound.com Wed, 04 Mar 2026 07:32:32 +0000 en-US hourly 1 https://wordpress.org/?v=6.9 https://design.crysound.com/wp-content/uploads/2025/08/cropped-icon-02-32x32.png Shop – Sound and Vibration Measurement & Testing – CRYSOUND https://design.crysound.com 32 32 IA3104 Contact Ultrasound Sensor https://design.crysound.com/product/ia3104-contact-ultrasound-sensor/ Tue, 06 Jan 2026 03:54:18 +0000 https://www.crysound.com/product/ia3104-contact-ultrasound-sensor/ The Contact Ultrasound Sensor is designed for detecting leakage in pressurized gas and liquid valves. Using contact ultrasonic sensing, ultrasound energy travels through the metal surface, and accurately captures high-frequency ultrasonic signals generated by internal valve leakage. Combined with intelligent analytics and a guided workflow, it automates the full process—from data acquisition and feature extraction to leak diagnosis—improving inspection efficiency and consistency in industrial environments. It is ideal for preventive maintenance and fault diagnostics of critical assets such as oil pipeline valves and natural gas network valves, supporting predictive maintenance decisions.

]]>
CRY3408-S01 Pressure-field Prepolarized High-level Microphone Set, 1/4″, 0.14mV/Pa https://design.crysound.com/product/cry3408-s01-pressure-field-prepolarized-high-level-microphone-set-1-4-0-14mv-pa/ Thu, 11 Dec 2025 03:01:50 +0000 https://www.crysound.com/product/cry3408-s01-pressure-field-prepolarized-high-level-microphone-set-1-4-0-14mv-pa/ The CRY3408-S01 is a 1/4″ pressure field prepolarization measurement microphone and preamplifier set designed for high sound pressure level acoustic measurement.
It is capable of acoustic testing in extremely high sound pressure environments and can withstand sound pressure levels up to 180 dB. It is suitable for measuring sound characteristics in high-volume environments and evaluating and optimizing acoustic environments.

]]>
CRY3408 Pressure-field Microphone, 1/4″,Prepolarized high-level,0.14 mV/Pa https://design.crysound.com/product/cry3408-pressure-field-microphone-1-4prepolarized-high-level0-14-mv-pa/ Thu, 11 Dec 2025 03:00:21 +0000 https://www.crysound.com/product/cry3408-pressure-field-microphone-1-4prepolarized-high-level0-14-mv-pa/ The CRY3408 is a 1/4″ pressure-field prepolarized measurement microphone purpose-built for acoustic measurements in the most extreme sound pressure environments. Capable of withstanding up to 180 dB SPL without distortion, it delivers clean and reliable data where standard microphones fail.

From rocket engine test stands to industrial blast chambers, the CRY3408 captures acoustic data under conditions that would overload conventional measurement microphones — making it an essential tool for aerospace, defense, and heavy industry applications.

Why Engineers Choose the CRY3408

  • 180 dB maximum SPL — Purpose-built for the most demanding high-SPL environments in aerospace, defense, and heavy industry
  • Distortion-free at extreme levels — 0.14 mV/Pa sensitivity keeps the output signal within usable range even under acoustic shock waves
  • Prepolarized convenience — No external 200V polarization voltage needed; CCP/ICP compatible for fast field deployment
  • Compact and rugged — 1/4″ form factor fits tight test setups and survives harsh environments
  • Traceable accuracy — Calibrated to national and international standards for measurement confidence in critical applications

Applications

🚀 Rocket & Spacecraft Engine Testing

Rocket engine testing - extreme high SPL acoustic measurement environment for CRY3408

Measure acoustic emissions during static fire tests and launch sequences. The CRY3408 captures the extreme SPL generated by propulsion systems — often exceeding 170 dB at the test stand — providing critical data for structural vibro-acoustic analysis, launch pad design, and payload protection.

💥 Blast & Impulse Noise Testing

Space shuttle launch producing 180 dB SPL - measured with high-SPL microphones like CRY3408

Characterize the acoustic output of controlled explosions, airbag deployments, gunshots, and ballistic testing. The CRY3408’s 180 dB capability and pressure-field design ensure accurate capture of impulsive, high-energy acoustic events — essential data for defense, automotive safety, and regulatory compliance.

🏭 Heavy Industrial Noise Measurement

Heavy industrial turbine facility - high noise measurement environment for CRY3408 microphone

Measure and monitor extreme noise sources in power generation facilities, turbine test cells, steel mills, and heavy manufacturing plants where SPL routinely exceeds the range of standard measurement microphones. Critical for occupational noise assessment, source identification, and noise control engineering.

✈️ Aerospace Acoustic Fatigue Testing

Support structural acoustic fatigue analysis for aircraft fuselages, engine nacelles, and satellite components. Measure the high-SPL acoustic environment — including DFAT (Direct Field Acoustic Testing) — that these structures must survive over their operational lifetime.

Understanding High-SPL Microphone Design

Why is the sensitivity so low (0.14 mV/Pa)?

High-SPL microphones are intentionally designed with low sensitivity. At extreme sound pressure levels (170–180 dB), a standard microphone would produce output voltages that exceed the input range of measurement systems, causing clipping and distortion. The CRY3408’s 0.14 mV/Pa sensitivity ensures the output signal stays within usable range — even at 180 dB.

What does “prepolarized” mean?

A prepolarized microphone has a permanent electrical charge built into the diaphragm, eliminating the need for an external 200V polarization voltage. This simplifies deployment — you can power it directly via CCP/ICP constant current from your analyzer or data acquisition system.

How to Choose: 1/4″ Microphone Comparison

Feature CRY3408 CRY3401 CRY3402 CRY3403
Sound Field Pressure-field Free-field Pressure-field Free-field
Sensitivity 0.14 mV/Pa 15.8 mV/Pa 1.6 mV/Pa 4 mV/Pa
Max SPL 180 dB 144 dB
Best For Extreme high SPL General-purpose, low-noise High-freq coupler testing Ultra-high frequency
Typical Use Rocket / blast / industrial Environmental noise, QC Cavity measurements Ultrasonic R&D

Quick selection guide:

  • Extreme SPL (>160 dB)?CRY3408 — the only choice for blast and rocket testing
  • General-purpose measurement?CRY3401 (best all-rounder)
  • Coupler/cavity testing?CRY3402
  • Ultra-high frequency?CRY3403

Frequently Asked Questions

Can the CRY3408 be used for normal (lower SPL) measurements?

Technically yes, but it’s not recommended. The low sensitivity means the signal-to-noise ratio at normal SPL levels (60–100 dB) will be poor. For general-purpose measurements, use the CRY3401 (15.8 mV/Pa). The CRY3408 is optimized for environments above 130 dB.

What other equipment do I need?

A typical high-SPL measurement chain: CRY3408 → compatible preamplifier → data acquisition system or analyzer. Consider the CRY3408-S01 set for a ready-to-use package. Ensure your data acquisition system has sufficient input range and sampling rate for your application.

How do I protect the CRY3408 in blast testing?

While designed for extreme SPL, protect the microphone from direct debris impact, extreme temperatures, and corrosive gases. Use appropriate mounting hardware and protective grids. Contact CRYSOUND for application-specific guidance.

How often should the CRY3408 be calibrated?

Annual calibration is recommended to maintain traceable accuracy. For mission-critical applications (aerospace, defense), more frequent calibration may be required per your quality management system. CRYSOUND offers professional calibration services.

Related Products

Product Description
CRY3408-S01 Complete high-SPL microphone set — CRY3408 + preamplifier + cable, ready to use
CRY3401 1/4″ free-field microphone (15.8 mV/Pa) for general-purpose acoustic measurement
CRY3402 1/4″ pressure-field microphone for high-frequency coupler and cavity measurements
]]>
Acoustic Link https://design.crysound.com/product/acoustic-link/ Fri, 14 Nov 2025 06:46:06 +0000 https://www.crysound.com/product/acoustic-link/ Acoustic Link is a companion mobile application for the CRY8120 Series Acoustic Imaging Camera. It establishes a fast, stable Wi-Fi connection to the camera, enabling on-device preview of captured photos, videos, and inspection reports on your phone or tablet—no PC required. Engineers can also retrieve and review defect-specific visuals generated by the camera—such as gas-leak acoustic maps, partial-discharge patterns, and thermal images—directly in the app. Results can be saved locally and shared via the system share sheet to streamline communication with colleagues and customers. With a clear file list and guided preview workflow, engineers across field inspection, after-sales service, and production QA can pinpoint faults faster, document evidence consistently, and accelerate decision-making.]]> Acoustic Link is a companion mobile application for the CRY8120 Series Acoustic Imaging Camera. It establishes a fast, stable Wi-Fi connection to the camera, enabling on-device preview of captured photos, videos, and inspection reports on your phone or tablet—no PC required. Engineers can also retrieve and review defect-specific visuals generated by the camera—such as gas-leak acoustic maps, partial-discharge patterns, and thermal images—directly in the app. Results can be saved locally and shared via the system share sheet to streamline communication with colleagues and customers. With a clear file list and guided preview workflow, engineers across field inspection, after-sales service, and production QA can pinpoint faults faster, document evidence consistently, and accelerate decision-making. ]]> CRY578 Bluetooth LE Audio Interface https://design.crysound.com/product/cry578-bluetooth-le-audio-interface/ Wed, 15 Oct 2025 14:16:44 +0000 https://www.crysound.com/product/cry578-bluetooth-le-audio-interface/ CRY578 Bluetooth LE Audio Interface is a Bluetooth device specifically designed for Bluetooth audio and UI testing. It updates to Bluetooth v5.4 and supports LE Audio features. It is suitable for use in R&D laboratories and production line testing. It can be used in conjunction with CRY6151B audio analyzer, or as a standalone module in combination with other testing equipment. Users can control CRY578 Bluetooth LE Audio Interface using the Sonolab software or the independent CRY578 tool software for searching, pairing, connecting, playing audio, and recording, etc.

]]>
CRY8500 Series SonoCam Pi Acoustic Camera https://design.crysound.com/product/cry8500-series-sonocam-pi-acoustic-camera/ Wed, 15 Oct 2025 02:43:32 +0000 https://www.crysound.com/product/cry8500-series-sonocam-pi-acoustic-camera/ The SonoCam Pi is a hand-held acoustic camera development kit designed to support for quick and accurate sound imaging application.

With up to 208 MEMS microphones and an array larger than 30 cm in size, this development kit is capable of both near-field and far-field measurements in a single system. This high-performance, lightweight and portable development kit redefines mobility and precision in acoustic diagnostics, enabling it the ideal tool for acoustic testing and analysis.
The SonoCam Pi development kit is capable of both near-field and far-field measurements in a single system,which makes it suitable for a wide range of applications,such as acoustics laboratory research and testing,detecting mechanical faults or airborne noise,visualizing acoustic weak spots and radiating components,and optimizing sound quality in automotive and consumer electronics.

]]>
SonoDAQ Pro https://design.crysound.com/product/cry5820-sonodaq-pro/ Wed, 15 Oct 2025 02:38:55 +0000 https://www.crysound.com/product/cry5820-sonodaq-pro/ CRYSOUND has launched the new SonoDAQ Pro data acquisition system, seamlessly integrated with the OpenTest software platform. Featuring modular scaling from 4 to 24 channels per unit, up to 170 dB dynamic range, and PTP (IEEE 1588) / GPS synchronization with ≤100 ns delay, SonoDAQ Pro delivers stable, repeatable performance in both laboratory and field environments.

The system is widely applied in automotive NVH testing, aerospace, consumer electronics, and industrial machinery. By combining high-precision data acquisition with intelligent analysis, SonoDAQ and OpenTest provide a complete workflow—from multi-channel acquisition and real-time monitoring to advanced processing, automation sequences, and one-click reporting—significantly improving test throughput and engineering confidence.

]]>
CRY3018 Sound Calibrator https://design.crysound.com/product/cry3018-sound-calibrator/ Tue, 14 Oct 2025 07:15:32 +0000 https://www.crysound.com/product/cry3018-sound-calibrator/ The CRY3018 is a portable, high-precision acoustic calibrator compliant with IEC 60942:2017 Class 1. It supports dual frequencies of 250 Hz and 1000 Hz, as well as dual sound pressure levels of 94 dB and 114 dB, with the option to switch to higher SPLs to overcome ambient interference. It features an internal acoustic feedback compensation loop and integrates temperature, humidity, and barometric sensors for adaptive environmental compensation, ensuring linear response and consistent microphone measurements. Additional features include USB-C fast charging, a carbon-fiber housing, and a high-brightness OLED display—making it ideal for on-site calibration of sound level meters, measurement microphones, and acoustic systems.

]]>
OpenTest https://design.crysound.com/product/opentest/ Tue, 14 Oct 2025 03:00:37 +0000 https://www.crysound.com/product/opentest/ OpenTest is a next-generation platform designed for engineers, researchers, and manufacturers seeking precision, flexibility, and innovation in acoustic and vibration testing. Built on three core principles—Openness, AI-Driven Intelligence, and Boundless Compatibility—we empower industries like consumer electronics, automotive NVH, industrial diagnostics, and academic research to redefine quality control, accelerate R&D, and streamline production.

]]>
CRY2620 64-Mic Industrial Acoustic Imaging Camera https://design.crysound.com/product/cry2620-64-mic-industrial-acoustic-imager/ Fri, 22 Aug 2025 09:03:36 +0000 https://www.crysound.com/product/cry2620-64-mic-industrial-acoustic-imager/ The CRY2620 Industrial Acoustic Imaging Camera is designed for ease of use and quick operation. Its robust aluminum alloy shell ensures durability, making it adaptable to complex and changing work environments. The device provides a real-time sound image display, significantly accelerating the detection of pressurized or vacuum leaks compared to traditional methods.
The CRY2620 simplifies testing with just two adjustable parameters: test frequency range and dynamic range, covering most testing needs.
It offers multiple modes, including camera and video modes, along with flexible on-site data recording. The large-capacity MicroSD storage card is expandable, allowing for quick export and reporting of test results.
This device helps enterprises minimize losses from gas leaks and other accidents, enhancing overall operational safety.

]]>
CRY3213 NVH Measurement Microphone https://design.crysound.com/product/cry3213-nvh-measurement-microphone/ Wed, 06 Aug 2025 02:46:05 +0000 https://www.crysound.com/product/cry3213-nvh-measurement-microphone/ CRY3213 is a high-precision microphone specifically designed for demanding NVH testing. With an IP67 protection rating and an operating temperature range of –50°C to 125°C, it reliably performs in harsh environments such as high humidity, dust, and extreme temperatures, ensuring data accuracy in complex test conditions. It is an ideal solution for measuring powertrain noise, road noise, and wind noise in automotive applications.

]]>
CRY3718 Ear Simulator IEC60318-1 https://design.crysound.com/product/cry3718-ear-simulator-iec60318-1/ Sun, 08 Jun 2025 14:34:10 +0000 https://www.crysound.com/product/cry3718-ear-simulator-iec60318-1/ CRY3718 is a simulation ear specifically designed for measurements in audiology and related fields.

The unique design of CRY3718 enables it to carry out electroacoustic measurements of telephone receivers or headsets in a clear acoustic environment. It is widely utilized in research and development within the fields of headphones, hearing assistance devices, and other related areas.

]]>